ST501-PT100 ultrasonic energy meter

,

individual energy consumption meter

,

ultrasonic energy meter with warranty

Ukuran pipa:
1 ”~ 48” DN25-DN1200
Bahan pipa:
PVC, baja karbon, baja tahan karat ...
Cairan:
Air, air laut, minyak, alkohol ...
rentang kecepatan:
0 ~ ± 16ft/s (0 ~ ± 5m/s)
Ketepatan:
± 1,0% dari nilai yang diukur
Pengulangan:
0,3%
Jenis Sensor Suhu:
Penjepit
Suhu Operasional:
Suhu Sensor Suhu PT100: 32 ℉ ~ 257 ℉ (0 ℃ ~ 125 ℃)
Menampilkan:
20 × 2, alfanumerik, LCD backlit
Catu Daya:
24V DC@1MAX
Ukuran pipa:
1 ”~ 48” DN25-DN1200
Bahan pipa:
PVC, baja karbon, baja tahan karat ...
Cairan:
Air, air laut, minyak, alkohol ...
rentang kecepatan:
0 ~ ± 16ft/s (0 ~ ± 5m/s)
Ketepatan:
± 1,0% dari nilai yang diukur
Pengulangan:
0,3%
Jenis Sensor Suhu:
Penjepit
Suhu Operasional:
Suhu Sensor Suhu PT100: 32 ℉ ~ 257 ℉ (0 ℃ ~ 125 ℃)
Menampilkan:
20 × 2, alfanumerik, LCD backlit
Catu Daya:
24V DC@1MAX
Upgrade Your System with ST501-PT100 Ultrasonic Energy Meter for Individual Energy Consumption Measurement

ST501-PT100 Ultrasonic Energy Meter

Clamp-on type ultrasonic energy meters for cooling and heating consumption measurement.

 

Introduction

ST501 is a high-accuracy ultrasonic flow meter with clamp-on transducers measuring big pipe diameter, which is built-in RTD module. When it is equipped with PT100 temperature sensor, ST501 can be upgraded into energy meter used for measuring individual energy consumption in any liquid heating/cooling systems. The meter is supplied complete with flowmeter and temperature sensor, which can makes the system real-time detect the temperature of supply and return pipe.

The energy meter can be widely applied in various applications, like HVAC, cooling tower, data center, energy audit, and building(shipping mall, office, museum, hospital, school, subway etc.). Energy meter, also called thermal energy meter or heat meter, is used to accurately measure heat consumption in heating and cooling facilities so as to reach energy-saving and cost-saving.

 

Main Features

• Precise bi-directional and highly dynamic flow measurement with the non-intrusive clamp-on technology.

• High accuracy at fast and slow flow rates, high temperature and zero point stability.

• Water and liquids, tolerant of liquids with small amounts of air bubbles or suspended solids

• Automatic loading of calibration data and transducer detection for a fast and easy set-up, providing precise and long-term stable results.

• Clear and simple menu selections

• Clamp on transducer and insertion transducer versions

• Transducers available for a wide range of inner pipe diameters (25mm~1200mm) and fluid temperatures (0~60℃)

 

Principle

  • Introduction to TVT

TVT(Transit-Time Vortex) technology represents a cutting-edge approach to ultrasonic flow measurement, combining the principles of transit-time ultrasonics with the capability to harness the vortex shedding phenomenon, delivering unparalleled accuracy and versatility in ultrasonic flow meters. This innovative integration technology enhances the accuracy, versatility, and performance of ultrasonic flow meters, making them well-suited for a wide range of applications across various industries and is a valuable solution for industries requiring precise flow measurements in varying flow conditions.

 

  • Enhanced Accuracy in Turbulent Flows:

TVT technology excels in applications where fluid flow conditions vary between laminar and turbulent. The incorporation of vortex shedding data enhances accuracy in challenging flow environments.

  • Versatility in Fluid Types:

TVT technology is versatile and suitable for a wide range of fluid types, including liquids with varying viscosities and densities.

 

 

Specifications

 

Measurement General Data
Flow Flow Unit
Velocity Rate 0.03~±16ft/s(0.01 ~±5m/s) Support metric unit selection,
Cubic Meters(m³),Liters(l),
USA Gallons(gal)./hour,/min,The factory default unit is m³per hour.
Accuracy +1.0%
Repeatability 0.3%
Pipe Size DN25~DN1200(1”"~48")
Liquid Water,Sea water,Oil,Alcohol… Energy Unit
Pipe Material Carbon Steel,Stainless Steel,PVC… Giga Joule (GJ),Kilocalorie (Kc),
KWh,BTU
Power Supply 24 VDC
Cable Length 10m Totalizer
Key Panel 16(4×4)touch keys 6 bit flow rate totalizer.
Display 20×2,alphanumeric,backlit LCD Communication &Output
Ambient Temp 32°F~+140°F(0℃~60℃) ModBus RS485,4~20mA,
Maximum load:750Ω
OCT upper and lower limit alarm
Fluid Temp. 32°F~+140°F(0℃~60℃)
PT100 Temp.Sensor 32°F~257°F(0℃~125℃)
Ambient Humidity RH 0~95%,No condensation Housing Material
IP Rate Transmitter:IP65 Aluminum alloy
  Transducer:IP68  

 

 

Upgrade Your System with ST501-PT100 Ultrasonic Energy Meter for Individual Energy Consumption Measurement 0

Upgrade Your System with ST501-PT100 Ultrasonic Energy Meter for Individual Energy Consumption Measurement 1

Upgrade Your System with ST501-PT100 Ultrasonic Energy Meter for Individual Energy Consumption Measurement 2

Upgrade Your System with ST501-PT100 Ultrasonic Energy Meter for Individual Energy Consumption Measurement 3 

Upgrade Your System with ST501-PT100 Ultrasonic Energy Meter for Individual Energy Consumption Measurement 4

Produk serupa
ST501 PT100 Sensor Suhu Energi Meter Video
Dapatkan Harga Terbaik
Dapatkan Harga Terbaik
Meter Aliran Energi Untuk Air Dingin Video
Dapatkan Harga Terbaik
Dapatkan Harga Terbaik
ST502 RTD Ultrasonik Flowmeter Video
Dapatkan Harga Terbaik
Sistem Manajemen Bangunan Energi Meter Video
Meter Panas Ultrasonik Tetap Video
Dapatkan Harga Terbaik